Nuri Tojik

EQUIPMENT DOCUMENTS

Manufacturer certificates

Standards, scope and document details for GoodWe, Risen Energy and RONMA.

These documents were issued to the manufacturers for the equipment models specified in them. They do not constitute accreditation of Nuri Tojik or confirm authorized dealer status.

Document · 2 p.

GoodWe

HT 1500V inverter conformity

Manufacturer documents ↗
Document number
N8A 083373 0066 Rev. 00
Document holder
JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO., LTD.
Issuing body
TÜV SÜD Product Service GmbH
Issue date
23.11.2020
Validity stated in the document
No expiry date stated

Standards and requirements

  • EN 62109-1:2010
  • EN 62109-2:2011
  • 2014/35/EU

Models covered

GW225K-HT and GW250K-HT only — grid-connected inverters rated at 225 and 250 kW.

Attestation of Conformity under the Low Voltage Directive. The manufacturer issues the EU Declaration of Conformity separately. This document does not cover 125 kW models or all GoodWe inverters.

Document · 2 p.

Risen Energy

Salt mist testing of modules

Manufacturer documents ↗
Document number
Z2 082429 0198 Rev. 07
Document holder
Risen Energy Co., Ltd
Issuing body
TÜV SÜD Product Service GmbH
Issue date
29.11.2024
Validity stated in the document
until 01.07.2029

Standards and requirements

  • IEC 61701:2020
  • IEC 61215-1:2021
  • IEC 61215-1-1:2021
  • IEC 61215-2:2021
  • IEC 61730-1:2023
  • IEC 61730-2:2023

Models covered

The RSM series and power ranges listed on page 2. Salt mist test: method 6.

The copy provided is Rev. 07. Before ordering, check that the selected model is covered and verify the current revision of the certificate.

Document · 5 p.

RONMA

PV module testing and safety

RONMA website ↗
Document number
44 780 22 406749 - 171R1M2
Document holder
Shandong Ronma Solar Co., Ltd.
Issuing body
TÜV NORD CERT GmbH
Issue date
29.03.2023
Validity stated in the document
until 25.07.2027

Standards and requirements

  • IEC / EN 61215
  • IEC / EN 61730

Models covered

RM-series double-glass modules with 182M and 210M cells, as listed in Annex 2. The exact editions of the standards are stated on page 1.

The store model RM-620W-182R/132TB is not listed in these annexes. This PDF does not confirm certification of this 620 W model.

The information is based on copies provided to the company. Links lead to the manufacturers' websites. Dates are reproduced from the documents; current validity and applicability to the model being supplied should be confirmed with the manufacturer or certification body. Names and trademarks belong to their respective owners.

Go to store →

Contact Nuri Tojik

Dushanbe · near Mehrgon Market

+992 977 44 44 22Equipment certificates

Company email

nuri.tojik2025@gmail.comnuri.tojik.asosi@gmail.com

Follow us

Instagram · @nuri_tojik_electric ↗Facebook · Nuri Tojik Electric ↗